FL7000 OEM-style Variable Area Flow Meters are precisely machined from solid acrylic blocks. They are available in 50, 75, 100, 127, and 250 mm scale lengths (1.97, 2.96, 5, 3.94, and 9.85') and have accuracies between 2 and 6%.
SPECIFICATIONS Construction: Acrylic tube, 316 SS float and guide rod (no guide rod for FL7211 through FL7215 air meters), PVC end fittings (brass on FL7200 series), EPR O-rings Shipping Weights: FL7200, 7300, 7500: 0.45 kg (1 lb) FL7400: 0.79 kg (1.75 lb) FL7600: 1.25 kg (2.75 lb) Max Pressure/Temperature: Water Ranges: 125 psig at 21°C (70°F); 54°C (130°F) at 0 psig Air Ranges: 100 psig at 21°C (70°F); 38°C (100°F) @ 0 psig Full Scale Accuracy/Repeatability: FL7200: 6/2% FL7300: 6/1% FL7400: 4/1% FL7500: 3/½% FL7600: 2/½%
Rated 5 out of
5 by
JJewell from
Highly recommendAWESOME COMPANY TO DEAL WITH! We greatly appreciate the prompt communication and delivery times!
Date published: 2024-09-13
Rated 5 out of
5 by
Conteind Cau from
Quality productThe best quality on the market. Easy to read and good materials used.
Date published: 2022-10-11
Rated 5 out of
5 by
OhioRover from
Works as expectedThese rotameters are high quality and nicely finished. No issues.
Date published: 2016-11-28
Rated 4 out of
5 by
Dan C from
Very good productVery happy with this product. The only CON is the cost of the certs over 3 times the cost of the unit THAT'S RIDICULOUS!!
Thank you for your inquiry about the rotameter. The best way to mount is with rigid pipes when installing the rotameter in a vertical position, unfortunately, no mounting options available.
Answered by: Application Engineer JC
Date published: 2021-10-14
What are the thread size and pitch of the mounting holes on the back of the meter?
Asked by: JWW7
Thank you for your inquiry! The FL7000 series meters have 10-32 threads for mounting
Answered by: Application Engineer JM
Date published: 2022-10-19
What pressure/temperature is the SCFM of the air rotameters calibrated to?
Asked by: JJJJ
Thank you for your inquiry. The rotameters are calibrated to standard conditions at 21 C (70F) and 14.7 PSIA.