PST joins DwyerOmega. Read more>
SPECIFICATIONS | ||
OUTPUT RATINGS Horsepower: 90 to 132V, 1/4 to 1 hp 200 to 240V: 1/2 to 71/2 hp 380 to 480V: 1 to 10 hp 425 to 660V: 1 to 10 hp Frequency Range: 0.1 to 400 Hz Overload Rating: 150% for 60 sec Frequency Resolution: Digital: 0.1 Hz Analog: Max (set frequency/1000) Hz Frequency Accuracy: Digital: ±0.01% of max frequency Analog: ±0.2% of max frequency Undervoltage Carryover Limit: 0.3 to 25 sec MOTOR PERFORMANCE Motor Control: Sensorless vector Constant and Variable Torque: Standard Speed Regulation: 0.5% of base speed INPUT POWER Voltage: 50/60 Hz ±3 Hz 100 to 120V: -10% +10%/1-phase 200 to 240V: -10% +5%/1-phase 200 to 240V: -10% +5%/3-phase 380 to 480V: -10% +10%/3-phase 500 to 600V: -15% +10%/3-phase Displacement Power Factor: Better than 0.95 Efficiency: Typically greater than 95% DESIGN TYPE Microprocessor: 32-Bit Converter Type: Diode Inverter Type: Insulated gate bipolar transistor Waveform: Sensorless vector ENVIRONMENT Operating Temperature: -10 to 50°C (14 to 122ºF), -10 to 40°C (14 to 104ºF); above 71/2 hp) Humidity: 20 to 90%, non-condensing Max Elevation: 1000 m (3281') Codes and Standards: NEMA, IEEE, NEC, design standards, UL Listed, cUL listed, CE marked (requires EMI filter) Enclosure: Standard, protected chassis (IP20) PROTECTIVE FEATURES Ground Fault: Standard Overload Protection: Standard Overcurrent: Standard Overvoltage: Standard Undervoltage: Standard Overtemperature: Standard Overload Limit: Standard | SET UP ADJUSTMENTS, PERFORMANCE FEATURES, OPERATOR CONTROL AND EXTERNAL INTERFACE KEYPAD Alphanumeric Display: Standard, 1 x 4 character Digital Indications: Frequency (Hz), Motor Current (amps), User-Defined RUN/STOP, FORWARD/REVERSE and parameters Diagnostics: Last 3 trips with cause LED Status Indicators: 8; RUN/STOP, FORWARD/REVERSE, Hz, amps, user defined, and input speed Operator Functions: START/STOP, speed control (digital or potentiometer), RESET, SETUP keys and ENTER I/O TERMINAL BLOCK Analog Inputs: 2 Inputs; 0 to 10 Vdc, 4 to 20 mA Potentiometer: 1 to 2K Analog Voltage: Nominal 10 Vdc, 10K input impedance Analog Current: Nominal 4 to 20 mA 250 Digital Inputs: 6 programmable inputs Digital Outputs: 1 programmable open collector and 1 form C relay contact Analog Monitor Output: Analog meter; frequency or output current dynamic brake chopper PROGRAMMABLE PARAMETERS Out of the Box: Factory settings loaded for quick start-up Accel. and Decel.: 2 separately adjustable linear or S curve times; 0.1 to 3000 sec Auto Restart: Overcurrent, overvoltage and undervoltage with 4 selectable retry restart modes DC Injection Braking: External Fault: Terminal input Jog: Terminal input Fault Reset: STOP/RESET or terminal input I/O: NO/NC Selectable Jump Frequencies: 3; with adjustable width Parameter Security: Programmable software lock Preset Speeds: 7 preset speeds PID Controller: PID process control Reversing: Keypad or terminal Speed Setting: Keypad, terminal or pot START/STOP Control: Keypad or terminal Stop Modes: Decel, coast or DC injection RELIABILITY Pretested Components: Standard Surface Mount Technology: Standard(PCBs) Computerized Testing: Standard Final Test with Full Load: Standard Eaton's Cutler-Hammer Engineering Systems and Service: National network of AF drive specialists |
DESCRIPTION HORSEPOWER | VOLTS | DIMENSIONS IN MM(IN) | SHIPPING WEIGHT KG(LBS) | ||
---|---|---|---|---|---|
WIDTH | HEIGHT | DEPTH | |||
¼ to 1 | 100 - 120 | 100 (3.9) | 151 (5.9) | 145 (5.7) | 2.8 (6.2) |
½ to 2 | 200 - 240 | 100 (3.9) | 151 (5.9) | 145 (5.7) | 2.8 (6.2) |
3 to 7½ | 200 - 240 | 125 (4.9) | 220 (8.6) | 193 (7.6) | 5.5 (12.1) |
1 to 3 | 380 - 480 | 100 (3.9) | 151 (5.9) | 145 (5.7) | 2.8 (6.2) |
5 to 10 | 380 - 480 | 125 (4.9) | 220 (8.6) | 193 (7.6) | 5.5 (12.1) |