SPECIFICATIONS (D7PR RELAY)
Rated Load (Resistive Load*): 120/240 Vac 15 A, 30 Vdc 15 A
Rated Load (Inductive Load*): 120/240 Vac 10 A, 30 Vdc 7 A
Carry Current: 15 A
Max Operating Voltage: 250 Vac/125 Vdc
Max Operating Current: 15 A
Contact Material: AgCdO
Max Switching Capacity (Resistive Load*): 1700 VA 360 W
Max Switching Capacity (Inductive Load*): 1100 VA 170 W
Min Permissible Load: 100 mA, 5 Vdc
Pickup Voltage (Max): 80%
Drop Out Voltage (Min): 30% AC, 10% DC
Voltage (Max): 110%
Mechanical Life (Min): 10,000,000 AC, 100,000,000 DC
Electrical Life @ All Contact Ratings (Min): 200,000
Maximum hp Rating (Resistive Load*): 1.3 hp (120 Vac)
Maximum hp Rating (Inductive Load*): 1.2 hp (240 Vac)
* Resistive load p.f. = 1, inductive load p.f. = 0.4, L/R = 7 ms
SPECIFICATIONS (D7PF)
(RESISTIVE LOAD PF=1.0)
Coil Pickup Voltage (Max): 85% AC; 80% DC (% of nominal)
Coil Drop Out Voltage (Min): 10% AC; 10% DC (% of nominal)
Coil Maximum Voltage: 110% of nominal
Coil Insulation System per, UL
Standard 1446: Class B 130 °C (266 °F)
Contact Rated Load:
D7PF2: 120 Vac to 15 A , 277 Vac, 28 Vdc to 12 A, 220 Vdc to 0.5 A
D7PF4: 120 Vac, 28 Vdc to 15 A, 277 Vac to 12 A, 220 Vdc to 0.5 A
Maximum hp Ratings:
D7PF2: 1.2 hp, 120 Vac, 1 hp, 250 Vac
D7PF4: 1.2 hp, 120 Vac, 3.4 hp, 250 Vac
Contact Material: Silver alloy, gold flashed
Pilot Duty: B300
Utilization Category (IEC): AC-15
Min Permissible Load: 100 mA @ 5 Vdc or 0.5 W
Contact Resistance: 100 Milliohms, max @ 6V, 1 A
Dielectric Strength (Coil to Contacts): 2500 Vrms
Dielectric Strength (Across Open Contacts): 1000 Vrms
Dielectric Strength (Pole to Pole): 2500 Vrms
Insulation Resistance: 100 Megohms min @ 500 Vdc
Operating Temperature: -40 to 70 °C (-40 to 158 °F)
Storage Temperature: -40 to 105 °C (-40 to 221 °F)
Life Expectancy (At Rated Resistive), Load:
D7PF2: 200,000, operations
D7PF4: 150,000, operations
Life Expectancy (Mechanical at No Load): 10 million operations
Approximate Weight:
D7PF2: 36 g (0.079 lb)
D7PF4: 80 g (0.176 lb)