The OS4000 series high speed industrial fiber optic infrared transmitters measure temperature ranges from 200 to 1600ºC (392 to 2912°F) using three standard optical fields of view and three standard fiber optic cable lengths. This unit offers many standard features such as adjustable Emissivity, linear analog output, high and low alarm voltage output, RS232 PC interface, built-in laser sighting, etc. Through Windows based PC interface software, the user can select response time, Peak-Hold function, high and low alarm set points, and data logging. This unit is packaged in a space saving of 2.5" OD by 6" long. The mounting bracket and two mounting nuts are included.
PC Interface Software The OS4000 series comes with a Windows® based PC interface software. The software runs on Windows 2000, XP and Vista. The software allows the user to do the following:
Establish communication with the OS4001 and display temperature in real time both digitally and graphically
Select sound, COM port, and temperature engineering unit
Select the response time, and high and low alarm set points, and peak hold functions
Select chart scale either manual or automatic and chart time base
Display the temperature vs. time along with high and low alarm lines
Save the temperature data to a file
SPECIFICATIONS Power: 15 to 24 Vdc Temp Range: 100 to 1600°C (212 to 2912°F) Accuracy: 1% of Rdg Lens Probe Optical Field of Views: 5.6 @ 203 mm (0.22" @ 8") 2.2 @ 127 mm (0.086" @ 5") 0.63 @ 51 mm (0.025" @ 2") Fiber Optic Cable Lengths: 0.3, 0.9, 1.8, 3 m (1, 3, 6, 10') Emissivity: 0.05 to 0.99 adjustable Time Constant (0 to 63% Final Value): 1 msec (default) up to 3.2 seconds (programmable via PC software) Peak and Hold: Programmable via PC software Holding Time: 1 to 60 seconds Sample and Hold: Programmable via PC software Holding Time: 25 msec to 3.2 seconds Spectral Response: 1.2 to 2.6 microns Infrared Detector: InGaAs photo detector Analog Output: 0 to 5 Vdc, 0 to 10 Vdc, 4 to 20 mA, 1 mV/Deg PC Communication: RS232, 2-way Alarm Set Points: High and low programmable via PC software Alarm Output: Two voltage outputs, 30 mA drive Optional Built-in Relay: Two 10A @ 24 Vdc SPST NO relays (high and low) Operating Ambient Temperature: Transmitter: 0 to 50°C (32 to 122°F) Fiber Optic Lens Assembly: 0 to 150°C (32 to 302°F) Polymer Bolt Probe: Tip (425°C max), bolt (150°C) Glass Tip Assembly: Tip (425°C max), fiber junction (150°C) Quartz Tip Assembly: Tip (1000°C max), fiber junction (150°C) Glass or Quartz Rod Diameter: 0.080" Glass Tip Field of view: 1.2 (Distance to Spot size) Quartz Tip Field of view: 1.8 (Distance to Spot size) Laser Sighting Maximum Laser Power Output: Less than 1 mW Laser Beam Wavelength (Color): 650 nm (red) FDA Classification: Class II European Classification: Class 2 Beam Diameter: 5 mm (0.20") Dimensions: Transmitter: 63.5 OD x 152.4 mm L (2.5 x 6") Lens Probe: 25.4 OD x 190.5 mm L (1 x 7.5") Weight: 900 g (2 lbs)
Note: The head and cable must be calibrated as a pair, so order the Head and cable at the same time.